NEWS

/
/
/
Performance requirements for using lined fire hose

Performance requirements for using lined fire hose

Performance requirements for using lined fire hose

(Summary description)The fabric layer of the lining fire hose hose should be woven evenly and the surface should be clean; no double warp, broken double warp, weft jump or scratches.

Information

1. The fabric layer of the lining fire hose hose should be woven evenly and the surface should be clean; no double warp, broken double warp, weft jump or scratches.

2. Lining The thickness of the lining (or covering layer) of the fire hose hose should be uniform, and the surface should be smooth and flat, without wrinkles or other defects.

3. The nominal size and tolerance of the inner diameter of the lining fire hose hose should meet the requirements of Table 1.

4. The length and dimensional tolerance of the hose should meet the requirements of Table 2.

5. The design working pressure and pressure resistance value of the hose should not be lower than the requirements in Table 3.

6. ​​The mass per unit length of the hose.

(1) For hoses with design working pressures of 0.8 MPa, 1.0 MPa, 1.3 MPa, 1.6 MPa, the mass per unit length shall not exceed the provisions of Table 4.

table 4 g/m

(2) For hoses with a design working pressure of 2.0 MPa and 2.5 MPa, the mass per unit length shall not exceed the provisions of Table 5. [2]

7. For hoses with design working pressures of 0.8MPa, 1.0MPa, 1.3MPa, 1.6MPa, the axial elongation and diameter expansion rate should not be greater than 5% under the design working pressure. For hoses with design working pressures of 2.0MPa and 2.5MPa, their axial elongation and diameter expansion rate should not be greater than 8% under the design working pressure.

8. Under the action of water pressure, when viewed along the direction of water flow, the hose should not be twisted counterclockwise. Under the design working pressure, the degree of torsion should not be greater than that specified in Table 6.

9. Under 0.8MPa water pressure, bend the hose into an arc with an outer radius as specified in Table 7, and there should be no obvious wrinkles on the inner side of the curved part.

10. After the adhesion test is carried out according to 4 and 6, there should be no adhesion between the linings (or between the covering layers).

11. After conducting the low temperature resistance test according to 4 and 7, the hose should be able to unfold immediately without curling, and be able to be wound up again, and there should be no leakage under the design working pressure.

12. The lining (or covering layer) should have the following physical and mechanical properties.

(1) Adhesion strength

The adhesion strength between the fabric layer of the hose and the lining (or covering layer) should not be less than 20N/25mm.

(二) Elongation at break

The elongation at break of the hose lining (or covering layer) should be greater than the elongation at break of the fabric layer.

(3) Hot air aging

After the hot air aging test according to 4, 8, 1, and 3, the burst pressure of the hose and the adhesion strength of the lining (or cover) should not be less than 75% of the value measured before aging.

Scan the QR code to read on your phone

Recommended news
Seven points must be paid attention to when using common sense of lining fire hose
The lining fire hose is suitable for the transportation of liquid and non-corrosive powders. It should avoid contact with oil, acid, alkali and other corrosive chemicals.
Precautions for the use of lining fire hose interface
The interface is the connection between the hose and the hose, fire pump, fire hydrant, and mobile water monitor.
The shelf life of the lined fire hose
In the event of a fire, in addition to the use of fire extinguishers to extinguish the fire, the most commonly used are lining fire hoses. According to the fire protection code of building design, all residential districts and office buildings are now equipped with various specifications of lining fire hoses. So, how long is the shelf life of the fire hose?
How to maintain the lining fire hose in cold weather
The winter weather is starting to get cold, and companies that have equipped fire hoses are now considering how to do a good job in protection and maintenance. The first thing to consider is whether the hose can work normally in cold temperatures, and to ensure that it can work as usual in a low temperature of minus 20 degrees Celsius.

Nantong Sentian Fire-Fighting Equipment Co.,Ltd.

Service Hotline:

Address:

No.10, Yangsha Road,Qidong City,Jiangsu,China.

Message

Copyright © 2021  Nantong Sentian Fire-Fighting Equipment Co.,Ltd.     苏ICP备17053518号