Explain the maintenance skills of circular looms for you
(Summary description)Broken weft sensor: In the abnormal operation of the circular loom, when the weft is broken due to external force, the sensor detects the signal and transmits it to the controller to control the stop of the circular loom.
- Categories:Company News
- Author:
- Origin:
- Time of issue:2021-04-20 14:56
- Views:0
1. Broken weft sensor: In the abnormal operation of the circular loom, when the weft is broken due to external force, the sensor detects the signal and transmits it to the controller to control the stop of the circular loom. If the weft is broken, the machine will fail. Not time to stop automatically: jog the machine to make the yarn guide of one of the shuttles run under the sensor, manually pull the weft thread quickly, so that the steel ball enters the detection scale of the sensor, at this time, if the red indicator light of the sensor does not light up, adjust Position the sensor until the red indicator light turns on or the sensor is exchanged.
2. Finishing sensor: Wash the detector cover regularly (once every four hours). When the machine is running, make sure that the white light keeps on. The detector is in accordance with the infrared principle plan. The dazzling light will affect the function of the sensor. Only use daylight tube near the machine. For example, if the outside of the spindle is shiny, the detector may have no choice but to make precise things. Prevent the use of aluminum bobbin or black bobbin. The black yarn will make the detector helpless.
3. Upgrade detection sensor: If the man-machine interface cannot accurately record the output, check whether the wiring is accurate, such as the wiring is accurate, adjust the sensor position, run the machine, and check whether the indicator light flashes. If it does not flash, consider changing the sensor.
4. The main speed detection sensor: during mechanical abnormal operation, if the scale of the frequency conversion frequency jump is large, it may be that the sensor fails to detect the migration of the host due to the shock. At this time, it is necessary to adjust the position of the sensor so that the head of the sensor is aimed at the gear plate. , And then observe the promotion frequency conversion frequency, if it jumps in a small scale, it is fine, after repeated adjustments, the result cannot be achieved, exchange the sensor.
Our company's circular loom adopts man-machine interface operation: powerful function, centralized control, and convenient operation. Reliable active tracking detection and alarm parking for warp break, weft break and weft stop, and adopt advanced techniques such as frequency conversion speed regulation and vector promotion. The shuttle adopts the form of a roller, which is not smooth, low energy consumption, and reduced purification. This machine is mainly used to weave polypropylene, polyethylene flat yarn and other cylindrical fabrics. It is a production flexible collection bag, paper-plastic composite bag, geotextile, chemical bag Aspirational equipment such as plastic woven products. Welcome customers to call for mutual assistance.